Friday, 13 June 2014
On 10:01 by Unknown No comments
Danh mục sản phẩm > > Promag 53H > 53H15 UF0B1AC1ABAA
Electromagnetic flowmeter
PFA liner
010: Process Connection:
U: Welding nipple DIN11850, 316L/1.4404
020: Seal:
F: Aseptic shape, EPDM
030: Electrodes:
0: 1.4435/316L
040: Calibration:
B: 0.2%
050: Additional Test, certificate:
1: w/o
060: Approval:
A: Non-hazardous area
070: Housing:
C: Wall Alu, IP67 NEMA4X
080: Cable, Remote Version:
1: 5m/15ft coil and signal cable
090: Cable Entry:
A: Gland M20 (EEx d > thread M20)
100: Power Supply; Display:
B: 20-55VAC / 16-62VDC, WEA, 4-line + Touch control, WEA= language DE+EN+FR+IT+ES+PT+NL
110: Adjustment; Software Feature:
A: Factory setup; basic version
120: Output, Input:
A: 4-20mA SIL HART + frequency
120-A RUCKSACK
Assign current output: Volume flow
Current span: 4-20 mA HART NAMUR
Value 0/4 mA: 0dm3/min
Value 20 mA: 25dm3/min
Measuring mode: Standard
Time constant: 3s
Failsafe mode current output: Min. current
Assign pulse output: Volume flow
Pulse value (per pulse): 0.2dm3
Pulse width: 100ms
Output signal: Passive - positive
Failsafe mode pulse output: Fallback value
» Promag 53H - 53H65-5F0B1AA0ADAA: 0 VND (53H65-2877/0)
» Promag 53H - 53H80-5F0B1AA0ABAA: 0 VND (53H80-1QP9/0)
» Promag 53H - 53H65-A00B1AA0ABAA: 0 VND (53H65-10A1/0)
» Promag 53H - 53H50-A00B1AA0ABAA: 0 VND (53H50-10V6/0)
PFA liner
010: Process Connection:
U: Welding nipple DIN11850, 316L/1.4404
020: Seal:
F: Aseptic shape, EPDM
030: Electrodes:
0: 1.4435/316L
040: Calibration:
B: 0.2%
050: Additional Test, certificate:
1: w/o
060: Approval:
A: Non-hazardous area
070: Housing:
C: Wall Alu, IP67 NEMA4X
080: Cable, Remote Version:
1: 5m/15ft coil and signal cable
090: Cable Entry:
A: Gland M20 (EEx d > thread M20)
100: Power Supply; Display:
B: 20-55VAC / 16-62VDC, WEA, 4-line + Touch control, WEA= language DE+EN+FR+IT+ES+PT+NL
110: Adjustment; Software Feature:
A: Factory setup; basic version
120: Output, Input:
A: 4-20mA SIL HART + frequency
120-A RUCKSACK
Assign current output: Volume flow
Current span: 4-20 mA HART NAMUR
Value 0/4 mA: 0dm3/min
Value 20 mA: 25dm3/min
Measuring mode: Standard
Time constant: 3s
Failsafe mode current output: Min. current
Assign pulse output: Volume flow
Pulse value (per pulse): 0.2dm3
Pulse width: 100ms
Output signal: Passive - positive
Failsafe mode pulse output: Fallback value
» Promag 53H - 53H65-5F0B1AA0ADAA: 0 VND (53H65-2877/0)
» Promag 53H - 53H80-5F0B1AA0ABAA: 0 VND (53H80-1QP9/0)
» Promag 53H - 53H65-A00B1AA0ABAA: 0 VND (53H65-10A1/0)
» Promag 53H - 53H50-A00B1AA0ABAA: 0 VND (53H50-10V6/0)
Subscribe to:
Post Comments (Atom)
Search
Popular
-
ENDRESS+HAUSER Germany FMI51-A2AMRJB3A1A ENDRESS+HAUSER Germany 53H15-UF0B1AC1ABAA ENDRESS+HAUSER Germany...
-
RXWO-35 0.5A outdoor fuse guarantees the quality Jul 17, 2012 Tag: High tension fuse,load switch,electrification display unit,zinc oxide ...
-
N-Tron china 104TX Numatics china P22B-04AGM Numatics china AK3EF0000KLSTD Numatics china AK3EF0000KLSTD ...
-
Bosun china DQK 1422(220VAC ) Bosun china DQK 1422(220VAC ) Bosun china Coil 220V của DQK 1422(220VAC ) Bottarini ...
-
Lenze EVS9321-CPV003 LENZE E82EV751K4C040 LENZE PLC code : EPL-10200 LENZE Inverter code : EVS9326 -ES LENZE Inv...
-
FINETEK magnetic switch EFB-1420S with 3M cable. FINETEK FASC06 cable float level sensor FINETEK SP202-0-2U-A-0-0050+T...
-
Phonenix Contact Vietnam PSI-MOS-RS422/FO 850 E Replaced by: 2708355 (PSM-EG-RS422/F0-GST 2799898) Phonenix Contact Vietnam IBS I...
-
RELECO C5-A30/DC220V R RELECO CT3-W30/L UC20-65V R RELECO S3-B R RELECO C3-A30FX/DC24V ...
-
Sanyo china F734A0546 ( C SIZE) Sanyo china C-SB373H8A Sanyo china C-SB373H8A Sanyo Denki D.C.TACHOMETER...
-
Turn limit TOH =>SW-TOH CKD SENSOR AP - 33A KEYENCE PUSH BUTTON SWITCH ABN3G11G ...