Tuesday, 2 December 2014
RXWO-35 0.5A outdoor fuse guarantees the quality
Jul 17, 2012 Tag: High tension fuse,load switch,electrification display unit,zinc oxide arrester,

The high-pressure current-limiting fuse of indoor of Model RN1, over load and short circuit protection used for electric power circuit. The so-called current limiter is the function that the fuse cuts off it before the short circuit current reach the crest value.
Blowout characteristic:
When the electric current which passes the fuse is 1.3 times of its rated current, do not fuse for an hour;
When the electric current which passes the fuse is 2 times of its rated current, the blowout in an hour
The high-pressure current-limiting fuse of indoor of Model RN2, for the protection of the potential transformer, the capacity of its cutout is 1000MVA. On-off while going on in wink by way of minimum value of limiting the line current the most while shorting out, the fusing current should be within the range of 0.6-1.8A in one minute.
Daily fuse type:
RW3-10/100A; RW3-10/200A; HRW3-10/100A; HRW3-10/200A; RW10-10F/100A; RW10-10F/200A; HRW10-10F/100A; HRW10-10F/200A; RW11-10/100A; RW11-10/200A; HRW11-10/100A; HRW11-10/200A; RW5-10/100A; HRW5-10/200A; RW7-10/100A; HRW7-10/200A; RW5-35/100A; HRW5-35/100A; PRWG2-35/100A; HPRWG2-35/100A; RW9-35/0.5A; RW10-35/100A; RWXO-35/0.5A;
XRNP1-10/0.5A; XRNP1-10/1A; XRNP1-10/2A; XRNP1-10/3A ; XRNP1-10/3.15A ; XRNP1-12/0.5A; XRNP1-12/1A ; XRNP1-12/2A; XRNP1-12/3A ; XRNP1-12/3.15A; XRNP1-35(40.5) /1-3.15A; XRNT1-10/3.15-40A; XRNT1-12/3.15-40A; XRNT1-10/50-100A; XRNT1-12/50-100A; XRNT1-10(12) /125A; XRNT1-10(12/) 160; XRNT1-10(12) /200A ; XRNT1-40.5/3.15-40A; XRNT1-35/3.15-40A; RN1-6(10) /2-25A; RN1-6(10) /30-75A; RN2-6(10) /0.5-20A; RN2-6(10) /30-100A; RN3-10/100-200A
Subscribe to:
Post Comments (Atom)
Search
Popular
-
SENCON 11H-387-S1 Smart Sensor (Excludes Cable) – Part No: 311-38700-01 SENCON 11-247-03 Short Can Sensor (Excludes Cabl...
-
RXWO-35 0.5A outdoor fuse guarantees the quality Jul 17, 2012 Tag: High tension fuse,load switch,electrification display unit,zinc oxide ...
-
Norgen cylinder code: RM/930H/100 correct code: RM/930/100 Norgen VALVE 11-002-061 Norgen pressure meter 18-013-212...
-
ENDRESS+HAUSER Germany FMI51-A2AMRJB3A1A ENDRESS+HAUSER Germany 53H15-UF0B1AC1ABAA ENDRESS+HAUSER Germany...
-
FINETEK magnetic switch EFB-1420S with 3M cable. FINETEK FASC06 cable float level sensor FINETEK SP202-0-2U-A-0-0050+T...
-
Phoenix Contact Vietnam Code Phoenix Contact Vietnam 2866446 MINI-PS-100-240AC/24DC/1.3 Phoenix Conta...
-
Phonenix Contact Vietnam PSI-MOS-RS422/FO 850 E Replaced by: 2708355 (PSM-EG-RS422/F0-GST 2799898) Phonenix Contact Vietnam IBS I...
-
UE 12-S-L-S-N-4G-M201 UE 12-S-L-S-N-4C-M201 UE 12-S-L-S-N-4QA-M201 UE 12-S-L-S-N-4G-M201 UE H100-703 range: 0-...
-
Auberins Model : TC-K6 K type thermocouple (6ft cable) Auberins thermometer Auer QBX LED multi strobe beacon size 4, 3 stro...
-
ZD 51K120RGU-CF (220V120W 0,92AA 90-1350rpm) 5GU 7.5KB US5120-02 ZD 51K90RGN-CF ZD 5GN-10K Zellweger Minimax-4-OFCH...
0 comments:
Post a Comment