Danh mục sản phẩm > > Promag 53H > 53H15 UF0B1AC1ABAA
Electromagnetic flowmeter
PFA liner
010: Process Connection:
U: Welding nipple DIN11850, 316L/1.4404
020: Seal:
F: Aseptic shape, EPDM
030: Electrodes:
0: 1.4435/316L
040: Calibration:
B: 0.2%
050: Additional Test, certificate:
1: w/o
060: Approval:
A: Non-hazardous area
070: Housing:
C: Wall Alu, IP67 NEMA4X
080: Cable, Remote Version:
1: 5m/15ft coil and signal cable
090: Cable Entry:
A: Gland M20 (EEx d > thread M20)
100: Power Supply; Display:
B: 20-55VAC / 16-62VDC, WEA, 4-line + Touch control, WEA= language DE+EN+FR+IT+ES+PT+NL
110: Adjustment; Software Feature:
A: Factory setup; basic version
120: Output, Input:
A: 4-20mA SIL HART + frequency
120-A RUCKSACK
Assign current output: Volume flow
Current span: 4-20 mA HART NAMUR
Value 0/4 mA: 0dm3/min
Value 20 mA: 25dm3/min
Measuring mode: Standard
Time constant: 3s
Failsafe mode current output: Min. current
Assign pulse output: Volume flow
Pulse value (per pulse): 0.2dm3
Pulse width: 100ms
Output signal: Passive - positive
Failsafe mode pulse output: Fallback value
» Promag 53H - 53H65-5F0B1AA0ADAA: 0 VND (53H65-2877/0)
» Promag 53H - 53H80-5F0B1AA0ABAA: 0 VND (53H80-1QP9/0)
» Promag 53H - 53H65-A00B1AA0ABAA: 0 VND (53H65-10A1/0)
» Promag 53H - 53H50-A00B1AA0ABAA: 0 VND (53H50-10V6/0)
![]() |
PFA liner
010: Process Connection:
U: Welding nipple DIN11850, 316L/1.4404
020: Seal:
F: Aseptic shape, EPDM
030: Electrodes:
0: 1.4435/316L
040: Calibration:
B: 0.2%
050: Additional Test, certificate:
1: w/o
060: Approval:
A: Non-hazardous area
070: Housing:
C: Wall Alu, IP67 NEMA4X
080: Cable, Remote Version:
1: 5m/15ft coil and signal cable
090: Cable Entry:
A: Gland M20 (EEx d > thread M20)
100: Power Supply; Display:
B: 20-55VAC / 16-62VDC, WEA, 4-line + Touch control, WEA= language DE+EN+FR+IT+ES+PT+NL
110: Adjustment; Software Feature:
A: Factory setup; basic version
120: Output, Input:
A: 4-20mA SIL HART + frequency
120-A RUCKSACK
Assign current output: Volume flow
Current span: 4-20 mA HART NAMUR
Value 0/4 mA: 0dm3/min
Value 20 mA: 25dm3/min
Measuring mode: Standard
Time constant: 3s
Failsafe mode current output: Min. current
Assign pulse output: Volume flow
Pulse value (per pulse): 0.2dm3
Pulse width: 100ms
Output signal: Passive - positive
Failsafe mode pulse output: Fallback value
» Promag 53H - 53H65-5F0B1AA0ADAA: 0 VND (53H65-2877/0)
» Promag 53H - 53H80-5F0B1AA0ABAA: 0 VND (53H80-1QP9/0)
» Promag 53H - 53H65-A00B1AA0ABAA: 0 VND (53H65-10A1/0)
» Promag 53H - 53H50-A00B1AA0ABAA: 0 VND (53H50-10V6/0)
Subscribe to:
Post Comments (Atom)
Search
Popular
-
RXWO-35 0.5A outdoor fuse guarantees the quality Jul 17, 2012 Tag: High tension fuse,load switch,electrification display unit,zinc oxide ...
-
SENCON 11H-387-S1 Smart Sensor (Excludes Cable) – Part No: 311-38700-01 SENCON 11-247-03 Short Can Sensor (Excludes Cabl...
-
FINETEK magnetic switch EFB-1420S with 3M cable. FINETEK FASC06 cable float level sensor FINETEK SP202-0-2U-A-0-0050+T...
-
ENDRESS+HAUSER Germany FMI51-A2AMRJB3A1A ENDRESS+HAUSER Germany 53H15-UF0B1AC1ABAA ENDRESS+HAUSER Germany...
-
Auberins Model : TC-K6 K type thermocouple (6ft cable) Auberins thermometer Auer QBX LED multi strobe beacon size 4, 3 stro...
-
Phonenix Contact Vietnam PSI-MOS-RS422/FO 850 E Replaced by: 2708355 (PSM-EG-RS422/F0-GST 2799898) Phonenix Contact Vietnam IBS I...
-
Norgen cylinder code: RM/930H/100 correct code: RM/930/100 Norgen VALVE 11-002-061 Norgen pressure meter 18-013-212...
-
Sanyo china F734A0546 ( C SIZE) Sanyo china C-SB373H8A Sanyo china C-SB373H8A Sanyo Denki D.C.TACHOMETER...
-
Phoenix Contact Vietnam Code Phoenix Contact Vietnam 2866446 MINI-PS-100-240AC/24DC/1.3 Phoenix Conta...
-
KUEBLER 8.5020.0851.1024.0022 Kuebler 8.0000.6201.0005 (with 5m cable) Kuebler 8.5020.2851.1024 Kuebler 8.3...